Mechanism Overview
(1) Independent indication system for standalone use
- A single row of LEDs directly is switched on and off by a small magnet.
- A magnetic float moves along the row of LEDs.
- As the magnetic float moves along the LEDs, they are sequentially switched on or off according to the direction.
- The position of the magnetic float is indicated by the LEDs.
(2) External indication system
- A sensor detects movement of the magnetic float, transmitting a signal to the control unit.
- The liquid level can be checked remotely with a computer.
- The LED pattern used to indicate the liquid level can be set beforehand.
- Malfunctions and failures are self-diagnosed.
- Offsets between the float and liquid level can be adjusted using the relative density of the liquid.